Low Voltage | Single Phase Hybrid Inverter
The battery charge and discharge current up to 120A
Battery side high frequency transformer isolation, safe and reliable
Off grid peak power can reach twice of rated power (15S)
10ms switching
Up to 110%oversizing (1.3 times s60s)
UPS switch over time<10ms
Up to 2 times input
Support 110%three-phase unbalanced output
The maximum current of a single string module is 10A
Supports a maximum of 12 parallel three-phase units;16 single-phase units
Waterproof grade IP66
Support dry contact starting generator
Normal operation of olny-connection PV panels
Dual back up output
Model | AU3KESL | AU3.6KESL | AU4KESL | AU4.6KESL | AU5KESL | AU6KESL |
Battery input data | ||||||
Battery Type | Lithium or lead acid battery | |||||
Rated battery voltage(V) | 48 | |||||
Maximum charging voltage(V) | ≤60(Configurable) | |||||
Maximum charge/discharge current(A) | 120 | |||||
PV input data | ||||||
Maximum DC input voltage(V) | 500 | |||||
MPPT Operating voltage range(V) | 100~500 | |||||
Starting voltage(V) | 125 | |||||
Maximum input current(A) | 18 | 18/18 | 18/18 | 18/18 | 18/18 | 18/18 |
MPPT number | 1 | 2 | 2 | 2 | 2 | 2 |
AC output parameters (On-Grid) | ||||||
Maximum output apparent power (KW) | 3300 | 3960 | 4400 | 5060 | 5500 | 6000 |
Rated output voltage(V) | 230 | |||||
Rated output frequency(Hz) | 50/60HZ | |||||
Max output current(A) | 15 | 18 | 19 | 22 | 25 | 27 |
Output power factor | ~1 (-0.8 leading~+0.8 lagging) | |||||
AC output parameters(Off-Grid) | ||||||
Rated output apparent power(VA) | 3000 | 3600 | 4000 | 4600 | 5000 | 6000 |
Maximum output apparent power(VA) | 6000,15sec | 7200,15sec | 8000,15sec | 9200,15sec | 10000,15sec | 10000,15sec |
Rated output voltage(V) | 230(±2%) | |||||
Rated output frequency(Hz) | 50/60(±0.2%) | |||||
Max output current(A) | 15 | 18 | 19 | 22 | 25 | 27 |
Efficiency | ||||||
Max efficiency(PV) | 97.6% | |||||
Max efficiency(cell) | 94.5% | |||||
Europe efficiency | 97% | |||||
Protection | ||||||
PV input reverse polarity protection | Yes | |||||
PV insulation resistance detection | Yes | |||||
Residual current detection | Yes | |||||
Output over current protection | Yes | |||||
Output short circuit protection | Yes | |||||
Output over voltage protection | Yes | |||||
Basic data | ||||||
Operation temperature (°C) | -25~60 | |||||
Storage temperature (°C) | -30~65 | |||||
Relative humidity | 0~95% | |||||
Working altitude (m) | ≤4000 | |||||
Cooling | Air cooling | |||||
Noise (db) | <25 | |||||
Weight (Kg) | 19 | |||||
Size (width x height x depth) (mm) | 424*555*197 | |||||
Protection class | IP66 | |||||
Topology | HF isolation (Battery side) |