Hybrid Inverter
168-648V High Voltage
High-performance Safety Cells
Battery Module | 2 | 3 | 4 | 5 | 6 |
Rated capacity (kWh) | 5.18 | 7.77 | 10.36 | 12.96 | 15.55 |
Available Capacity (KWh) | 4.66 | 6.99 | 9.32 | 11.66 | 13.99 |
Rated voltage (V) | 192 | 288 | 384 | 480 | 576 |
Operating voltage (V) | 168-216 | 252-324 | 336-432 | 420-540 | 504-648 |
Max. continuous discharge current (A) | 27(1C) | ||||
Max. discharge power (kW) | 4.14 | 6.21 | 8.28 | 10.36 | 12.44 |
Battery Module(single pack) | 96-2.59KWh | ||||
Cell Type | IFP20100140A-27Ah | ||||
Cell Configuration | 60S1P | 90S/1P | 120S/1P | 150S/1P | 180S1P |
Technical Description | |||||
Charging Operating Temperature | 0°C~50°C |
||||
Disharging Operating Temperature | -20°C~50°C |
||||
Storage Temperature | -20~45°C (≤1 month) 0~35 °C (≤1 year) SOC:≥50% |
||||
Life Cycles | ≥6000 @0.5C/0.5C,25°C |
||||
Altitude(m) | ≤2000 | ||||
Protection | IP65 | ||||
Communication | CAN | ||||
Cooling | Natural | ||||
Installation | Overlay landing | ||||
Dimension(W×H×D mm) | 600×590×240 | 600×770×240 | 600×950×240 | 600×1130×240 | 600×1310×240 |
Weight(kg) | 70.1 | 97.9 | 125.7 | 153.5 | 181.3 |
Rated Capacity | Test conditions: cell voltage 2.5V-3.65V, 25±3°C temperature range, 0.5°C charge and discharge | ||||
Available Capacity | Test conditions: 90% depth of discharge, 25±3°C temperature range, 0.5°C charge and discharge |